集成四通道脑电记录的多模式经颅电刺激系统开发

      Development of a Multimodal Transcranial Electrical Stimulation System with Integrated Four-Channel EEG Recordings

      • 摘要: 为了提高经颅电刺激治疗效果并针对不同程度病患实现个性化治疗,该文设计了一种集成四通道脑电记录的多模式经颅电刺激系统,能够在刺激前、刺激中、刺激后实时监测脑电信号并进行相关特征分析,便于医生和科研工作者解析大脑当前状态,实时评价经颅电刺激效果,进而人为调整刺激参数。经过相关测试验证,该系统可以选择TACS、TDCS、TPCS、TRNS四种刺激模式,能够输出±2 mA范围内0.03 mA精度的恒定刺激电流,以及低频0~4 kHz(精度0.1 Hz)、高频50~100 kHz的刺激频率,能够在刺激干扰下获得较为准确的脑电信号,具有良好的市场应用前景。

         

        Abstract: In order to improve the effect of transcranial electrical stimulation treatment and realize personalized treatment for patients with varying severity levels, this paper designed an integrated four-channel EEG recording multimodal transcranial electrical stimulation system. This system can conduct real-time monitoring on EEG and related characteristic analysis before stimulation, in stimulation, and after stimulation. This enables physicians and researchers to resolve real-time brain states, evaluate transcranial electrical stimulation effect, and then artificially adjust the stimulation parameters. After relevant testing and verification, the system can select four stimulation modes: TACS, TDCS, TPCS and TRNS, which can output the constant stimulation current of 0.03 mA accuracy in the range of ±2 mA and the stimulation frequency of low frequency of 0~4 kHz (precision of 0.01 Hz) and high frequency 50~100 kHz, which can obtain more accurate EEG signals under stimulation interference, demonstrating a good market application prospect.

         

      /