Research Progress of Blood Pressure Measurement by Oscillometric Method
-
摘要: 血压是能反映出人体心脏和血管功能的重要生理指标。相比于其它方法,示波法具有抗噪能力强,操作简单和成本较低的优点,是目前应用最为广泛的血压测量技术。该文对近年来采用示波原理测量血压的关键技术进行了概述和讨论,即振荡波包络前处理方法和血压估计技术。其中估计技术包括传统示波法,基于波形形态学的方法,基于模型的方法和机器学习的方法。最后对其未来发展方向进行了展望。Abstract: Blood pressure is an important physiological index that can reflect the function of the heart and blood vessels. Compared with other methods, oscillometric measurement has the advantages of strong noise immunity, simple operation and low cost, which is the most widely used technology for blood pressure measurement. In this paper, we reviewed and discussed the key technologies of measuring blood pressure, such as pre-processing method of oscillation envelope and blood pressure estimation technique. The latter include traditional wave method, waveform morphology method, the methods based on the model and machine learning. At last, we have a look forward to its future development direction.
-
-
[1] Jones D W, Hall J E. Hypertension:pathways to success[J]. Hypertension, 2008, 51(5):1249-1251.
[2] 邓静. 柯氏音法与示波法结合的新型血压测量方法研究[D]. 哈尔滨:哈尔滨工业大学, 2010. [3] 许怀湘, 房兴业. 采用示波原理间接测量血压方法的进展[J]. 航天医学与医学工程, 2000, 13(3):231-234.. [4] 蒋巍巍, 季忠. 无创血压测量方法的研究进展[J]. 中华高血压杂志, 2015(7):685-689. [5] Antonova M L. Noninvasive determination of arterial elasticity and blood pressure. Part I:arterial volume pulsations and elastogram[J].Blood Press Monit, 2013, 18(1):32-40.
[6] 温亮, 李振波, 陈佳品, 等. 基于高斯拟合的神经网络血压测量算法[J]. 传感器与微系统, 2014, 33(4):132-134. [7] Forouzanfar M. A modeling approach for coefficient-free oscillometric blood pressure estimation[D]. Ottawa, Canada:University of Ottawa, 2014.
[8] Medero R. Determination of oscillometric blood pressure by linear approximation:US, US5577508[P]. 1996.
[9] Chen S. Improving algorithms for oscillometric blood pressure estimation by suppressing breathing effects[D]. Ottawa, Canada:University of Ottawa, 2010.
[10] 江国泰, 蒋大宗. 非创伤性血压测量的理想化力学模型及其参数辨识[J]. 中国生物医学工程学报, 1991(3):167-173. [11] Abolarin D. Non-invasive estimation of blood pressure using harmonic components of oscillometric pulses[D]. Ottawa, Canada:University of Ottawa, 2016.
[12] Marom O, Seidmann A. Standard algorithm for blood pressure measurement by sphygmo-oscillographic method[J]. Med Biol Eng Comput, 1996, 34(1):82-83.
[13] Barbe K, Van Moer W. An innovative oscillometric blood pressure measurement:Getting rid of the traditional envelope[C]. MeMeA, 2012:1-6.
[14] Mafi M, Rajan S, Bolic M, et al. Blood pressure estimation using oscillometric pulse morphology[C]. EMBC, 2011:2492-2496.
[15] Liang F, Takagi S, Himeno R, et al. A computational model of the cardiovascular system coupled with an upper-arm oscillometric cuff and its application to studying the suprasystolic cuff oscillation wave, concerning its value in assessing arterial stiffness[J]. Comput Meth Biomech Biomed, 2011, 16(2):141-157.
[16] Babbs C F. Oscillometric measurement of systolic and diastolic blood pressures validated in a physiologic mathematical model[J]. Biomed Eng Online, 2012, 11:1-12.
[17] Ursino M, Cristalli C. A mathematical study of some biomechanical factors affecting the oscillometric blood pressure measurement[J]. IEEE Trans Biomed Eng, 1996, 43(8):761.
[18] Lecun Y, Bengio Y, Hinton G. Deep learning[J]. Nature, 2015, 521(7553):436-444.
[19] Colak S, Isik C. Blood pressure estimation using neural networks[C]. IEEE CIMSA, 2004:21-25.
[20] Forouzanfar M, Balasingam B, Dajani H R, et al. Mathematical modeling and parameter estimation of blood pressure oscillometric waveform[C]. MeMeA, 2012:1-6.
[21] Forouzanfar M, Ahmad S, Batkin I, et al. Model-based mean arterial pressure estimation using simultaneous electrocardiogram and oscillometric blood pressure measurements[J]. IEEE TIM, 2015, 64(9):2443-2452.
计量
- 文章访问数: 96
- HTML全文浏览量: 9