血管力学特性测试装置

郭占社, 宋珂, 梁向党, 李博宇

郭占社, 宋珂, 梁向党, 李博宇. 血管力学特性测试装置[J]. 中国医疗器械杂志, 2017, 41(1): 51-55. DOI: 10.3969/j.issn.1671-7104.2017.01.014
引用本文: 郭占社, 宋珂, 梁向党, 李博宇. 血管力学特性测试装置[J]. 中国医疗器械杂志, 2017, 41(1): 51-55. DOI: 10.3969/j.issn.1671-7104.2017.01.014
Guo Zhanshe, Song Ke, Liang Xiangdang, Li Boyu. Testing Equipment on Vascular Mechanical Properties[J]. Chinese Journal of Medical Instrumentation, 2017, 41(1): 51-55. DOI: 10.3969/j.issn.1671-7104.2017.01.014
Citation: Guo Zhanshe, Song Ke, Liang Xiangdang, Li Boyu. Testing Equipment on Vascular Mechanical Properties[J]. Chinese Journal of Medical Instrumentation, 2017, 41(1): 51-55. DOI: 10.3969/j.issn.1671-7104.2017.01.014

血管力学特性测试装置

基金项目: 

国际合作项目资助(2014DFA31230)

详细信息
    通讯作者:

    宋珂,E-mail:sk_1417@163.com

  • 中图分类号: R318.0

Testing Equipment on Vascular Mechanical Properties

  • 摘要: 血管力学特性参数是血管重要指标之一,对临床医学研究等具有重要意义。该文研制了一套全新的血管力学特性测试系统,不仅实现了常规的一维拉伸断裂实验,而且能对血管进行疲劳往复拉伸测试。该测试系统包括测试机械平台、基于FPGA的硬件测试电路及数据处理软件等。机械平台通过滚珠丝杠把电机的旋转运动转换为直线运动,为血管拉伸提供轴向拉力。滚珠丝杠与力学传感器相连接,用于实现对力学数据的读取。拉力作用下血管位移数据的读取通过光栅尺实现。对血管测试的结果表明误差在0.292%,该系统完全可以实现对血管力学特性的测试。
    Abstract: The vascular mechanical parameters are important indicators for human vascular and they play important roles in clinical research. This paper developed a new vascular mechanical properties testing system. This system not only realizes the tensile rupture test in one dimensional, but also the reciprocating tensile test for vascular, which provides more comprehensive experimental data and theoretical basis for the study of human vascular. The system consists of three parts:the mechanical platform, hardware circuit and upper computer system. The mechanical platform transforms the rotation movement of motor into linear movement via the structure of ball screw. And the ball screw and tension sensor are connected, which is used for mechanical data reading. The displacement data is collected by displacement sensor. Experiments show that the accuracy is better than 0.292%, and could meet the demand of the testing of vascular biomechanical characteristics.
  • [1] 钱秀清, 张昆亚, 张智河, 等. 基于膨隆实验的血管非线性力学特性确定方法[J]. 医用生物力学, 2012, 27(5):505-509.
    [2] 欧阳晨曦, 周飞, 王维慈, 等. 人股动脉血管的径向拉伸性能[J]. 中国组织工程研究与临床康复, 2008, 12(1):89-93.
    [3] 张一飞, 余明华, 唐杰, 等. 猪→ 人异种心脏移植中相关血管的生物力学特性[J]. 中国临床康复, 2006, 10(41):213-215.
    [4] 吕超霞, 李文春, 张兴华, 等. 门静脉高压症猪肺血管的生物力学特性[J]. 中国临床解剖学杂志, 2008, 26(1):95-98.
    [5] 刘维永, 金振晓, 顾春虎, 等. 去细胞猪主动脉瓣的构建及性能鉴定[J]. 中华医学杂志, 2005, 85(5):324-327.
    [6] 胡坚. 浅谈对电子万能强力机强力, 夹持片, 测试速度对强力指标的影响[J]. 中国科技纵横, 2014(16):60-60.
    [7] 周飞, 徐卫林, 欧阳晨曦, 等. 小口径微孔聚氨酯人造血管生物力学性能研究[J]. 医用生物力学, 2008,23(4):270-274.
    [8] 吴卫. 人体血管支架有限元分析与结构拓扑优化[J]. 大连:大连理工大学,2007.
    [9] 姜宗来. 心血管生物力学研究的新进展[J]. 医用生物力学, 2010, 25(5):313-315.
计量
  • 文章访问数:  7
  • HTML全文浏览量:  0
  • PDF下载量:  0
  • 被引次数: 0
出版历程
  • 收稿日期:  2016-05-24
  • 网络出版日期:  2024-02-19
  • 刊出日期:  2017-01-29

目录

    /

    返回文章
    返回